Product introduction:
The photoelectric direct reading water meter adopts the photoelectric direct reading technology to read the word wheel data, which can reduce the reading error to zero compared with the traditional pulse meter, and is an electronic remote water meter with zero error of electromechanical conversion in the automatic meter reading system.
Application Scenarios:
It is suitable for water quantity measurement in factory self-use and newly-built residential areas. It does not need continuous power supply. It reads instantaneous power supply and mechanical values. Remote monitoring and management are carried out through wired network to realize real-time data collection and monitoring, which is convenient for management personnel to master water consumption at any time.
Product features:
• High precision, stable measurement performance, small pressure loss;
• Low power consumption, stable transmission signal, long service life;
• Full range of machine IP68 protection design, long-term immersion work.
Technical advantages:
The product has been deeply cultivated for 20 years, and has the invention patent of photoelectric direct reading and the patent of semi-automatic meter reading;
High precision, directly read the dial value, the accuracy rate of 100;
Technical parameters:
|
Flow parameters |
|||||||||
|
Nominal caliber DN |
15 |
20 |
25 |
||||||
|
Flow range (Q3/Q1) |
160 |
125 |
100 |
160 |
125 |
100 |
160 |
125 |
100 |
|
Overload flow Q4(m³/h) |
3.125 |
5.0 |
7.875 |
||||||
|
Common flow Q3(m³/h) |
2.5 |
4.0 |
6.3 |
||||||
|
Boundary flow Q2(L/h) |
25.0 |
32.0 |
40.0 |
40.0 |
51.2 |
64.0 |
63.0 |
80.6 |
100.8 |
|
Minimum flow Q1(L/h) |
15.6 |
20.0 |
25.0 |
25.0 |
32.0 |
40.0 |
39.4 |
50.4 |
63.0 |
|
Q1 ~ Q2 error |
±5% |
||||||||
|
Q2 ~ Q4 error |
±2% |
||||||||
|
Performance parameters |
|||||||||
|
Temperature Class |
T30 |
||||||||
|
Maximum working pressure |
1.6Mpa |
||||||||
|
pressure loss |
<40Kpa |
||||||||
|
Protection level |
IP68 |
||||||||
|
Accuracy class |
Level 2 |
||||||||
|
Flow field sensitivity level |
U5D3 |
||||||||
|
Electromagnetic Compatibility Level |
E1 (residential, commercial and light industrial) |
||||||||
|
CLIMATIC AND MECHANICAL ENVIRONMENT SAFETY CLASS |
O (fixed installation outdoors) |
||||||||
Typical customer:
Large properties, residential areas, commercial buildings and other customers with centralized measurement. Such customers need centralized management of water consumption, photoelectric direct reading remote water meter can realize remote automatic collection and management, improve the accuracy and efficiency of metering and charging.
Frequently Asked Questions:
1. Is the measurement accuracy of photoelectric direct reading remote water meter reliable?
Answer: The photoelectric direct reading remote transmission water meter adopts photoelectric detection technology, which does not need on-site collection, thus avoiding the defects of traditional mechanical water meter such as easy damage and inaccurate measurement.
2. Is the data transmission of photoelectric direct reading remote water meter stable and reliable?
Answer: The photoelectric direct reading remote water meter adopts Mbus and RS485 communication technology to ensure the timely, accurate and safe transmission of data.
3. Is the maintenance cost of photoelectric direct reading remote water meter high?
Answer: photoelectric direct reading remote water meter, with high reliability and long life characteristics, low maintenance costs. At the same time, it also has automatic detection and alarm functions, once a failure occurs, it can be repaired in time, avoiding the waste of maintenance costs.